| Normal output |
|
|
BPH |
1,800 |
| Output max. |
|
|
BPH |
1,900 |
| Output min. |
|
|
BPH |
950 |
| Cycle time |
|
|
sec. |
8 |
| Total cycle time |
|
|
min. |
8.3 |
| Bottle length up to |
inch |
12,126 |
mm |
308 |
| Bottle diameter up to |
inch |
3,543 |
mm |
90 |
| Bottles per row |
|
|
bottles |
4 |
| Total bottles |
|
|
bottles |
252 |
| Total pocket carriers |
|
|
carriers |
68 |
| Heat up: |
|
|
|
|
| Total duration time |
|
|
sec. |
80 |
| Actual treatment time |
|
|
sec. |
10.7 |
| Caustic: |
|
|
|
|
| Total duration time |
|
|
min. |
5.3 |
| Bottles filled with caustic solution |
|
|
min. |
4 |
| Cool down: |
|
|
|
|
| Total duration time |
|
|
min. |
2.3 |
| Actual treatment time |
|
|
sec. |
0.4 |
| Actual Spray time: |
|
|
|
|
| Hot caustic |
|
|
sec. |
8 |
| Caustic II |
|
|
sec. |
8 |
| Warm water |
|
|
sec. |
8 |
| Fresh water / sanitizer max. |
|
|
sec. |
10.7 |
| Tank capacities: |
|
|
|
|
| Caustic I |
Gal. |
238 |
m³ |
0.9 |
| Caustic II |
Gal. |
40 |
m³ |
0.15 |
| Warm-water |
Gal. |
40 |
m³ |
0.15 |
| Water consumption for 0.5 l bottles |
Gal./h |
132 |
m³/h |
0.5 |
| Water consumption for 1-l VdF bottles |
|
|
m³/h |
0.7 |
| Water consumption for 1-l VdF bottles for hot discharge 55°C |
|
|
m³/h |
0.5 |
| Heat consumption heating caustic from 15°C to 80°C |
|
|
kJ x 1000 |
300 |
| Heat consumption during operation maintaining caustic 80°C |
|
|
kJ/h x 1000 |
270 |
| Heat consumption during operation maintaining caustic 80°C for 1-l VdF bottle for hot discharge 55°C |
|
|
kJ/h x 1000 |
300 |
| Connected load approx. |
|
|
kW |
5.3 |
| Gross machine weight approx. |
pounds |
12,125 |
t |
5.5 |
Consumption figures are based on freshwater temp. 8-13°C (46-55°F), effluent 35-43°C (95-109°F), bottle discharge 28-33°C (82-91°F), room temperature 15°C (55°F), bottle temperature at infeed 15°C (59°F)
Conversion factors: 1000 kJ ? 238.8 kcal ? 0.45 kg (0.99 lb) low pressure steam ? 0.278 kWh