| Performance |
bottles/h |
3,000 |
| Control range max. |
bottles/h |
3,150 |
| Control range min. |
bottles/h |
1,500 |
| Cycle time |
sec. |
7.2 |
| Running time |
min. |
8.2 |
| Bottle length up to |
mm |
262 |
| Bottle diameter up to |
mm |
90 |
| Bottles per row |
pieces |
6 |
| Bottles inside the machine |
pieces |
408 |
| Bottle cell carrier |
pieces |
72 |
| Pre-heating: |
|
|
| Total residence time |
sec. |
57.6 |
| Treatment time effective |
sec. |
14.4 |
| Caustic: |
|
|
| Total residence time |
min. |
5.4 |
| Bottles filled with caustic soak |
min. |
3.8 |
| Cooling down area: |
|
|
| Total residence time |
min. |
2.3 |
| Treatment time effective |
min. |
1.3 |
| Spraying time effective: |
|
|
| Hot caustic |
sec. |
9.6 |
| Caustic II |
sec. |
14.4 |
| Warm-water |
sec. |
14.4 |
| Cold-water |
sec. |
9.6 |
| Fresh-water max. |
sec. |
14.4 |
| Container contents: |
|
|
| Caustic I |
m³ |
1.3 |
| Caustic II |
m³ |
0.2 |
| Warm-water |
m³ |
0.15 |
| Cold-water |
m³ |
0.15 |
| Water consumption for 0,5 l bottles |
m³/h |
0.75 |
| Heat consumption while heating the caustic from 15°C to 80°C |
kJ x 1000 |
370 |
| Heat consumption while operating, caustic 80°C |
kJ/h x 1000 |
345 |
| Power connected load |
kW |
6 |
| Operating weight |
t |
7 |
Consumption specifications refer to fresh-water 8-13°C, wastewater 35-43°C, bottle infeed 28-33°,
room temperature 15°C, bottle temperature at infeed 15°C
Exchange ratio: 1000 kJ ≌ 238,8 kcal ≌ 0,45 kg low pressure steam ≌ 0,278 kWh