| Normal output |
|
|
BPH |
5,000 |
| Output max. |
|
|
BPH |
5,250 |
| Output min. |
|
|
BPH |
2,500 |
| Cycle time |
|
|
sec. |
5.8 |
| Total cycle time |
|
|
min. |
8.7 |
| Bottle length up to |
inch |
10.315 |
mm |
262 |
| Bottle diameter up to |
inch |
2.795 |
mm |
71 |
| Bottles per row |
|
|
bottles |
8 |
| Total bottles |
|
|
bottles |
728 |
| Total pocket carriers |
|
|
carriers |
96 |
| Heat up: |
|
|
|
|
| Total duration time |
|
|
sec. |
63.4 |
| Actual treatment time |
|
|
sec. |
11.5 |
| Caustic: |
|
|
|
|
| Total duration time |
|
|
min. |
6.0 |
| Bottles filled with caustic solution |
|
|
min. |
4.1 |
| Cool down: |
|
|
|
|
| Total duration time |
|
|
min. |
2.5 |
| Actual treatment time |
|
|
min. |
1.2 |
| Actual Spray time: |
|
|
|
|
| Hot caustic |
|
|
sec. |
7.7 |
| Caustic II |
|
|
sec. |
11.5 |
| Warm-water |
|
|
sec. |
11.5 |
| Cold-water |
|
|
sec. |
11.5 |
| Fresh water / sanitizer max. |
|
|
sec. |
11.5 |
| Tank capacities: |
|
|
|
|
| Caustic I |
gal. |
423 |
m³ |
1.6 |
| Caustic II |
gal. |
53 |
m³ |
0.2 |
| Warm-water |
gal. |
53 |
m³ |
0.2 |
| Cold-water |
gal. |
53 |
m³ |
0.2 |
| Water consumption for 0.5 l bottles |
gal./h |
330 |
m³/h |
1.25 |
Heat consumption heating caustic
from 15°C (59°F) to 80°C (176°F) |
|
|
kJ x 1000 |
500 |
Heat consumption during operation
maintaining 80°C (176°F) |
|
|
kJ/h x 1000 |
575 |
| Connected load approx. |
|
|
kW |
10 |
| Gross machine weight approx. |
pounds |
16,535 |
t |
7.5 |
Consumption figures are based on freshwater temp. 8-13°C (46-55°F), effluent 35-43°C (95-109°F), bottle discharge 28-33°C (82-91°F), room temperature 15°C (55°F), bottle temperature at infeed 15°C (59°F)
Conversion factors: 1000 kJ ? 238.8 kcal ? 0.45 kg (0.99 lb) low pressure steam ? 0.278 kWh